{{item.Desc}}
HP ISR4331-V/K9 Genel Bakış
Product Code
ISR4331-V/K9
Aggregate Throughput
100 Mbps to 300 Mbps
Total onboard WAN or LAN 10/100/1000 ports
3
RJ-45-based ports
2
SFP-based ports
Enhanced service-module (SM-X) slot
1
NIM (Network Interface Modules) slots
Onboard ISC slot
Memory
4 GB (default) / 16 GB (maximum)
Flash Memory
Power-supply options
Internal: AC and PoE
Rack height
1 RU
Dimensions (H x W x D)
44.45 x 438.15 x 438.15 mm
Package Weight
12.96 Kg
Figure 2 shows the front panel of Cisco ISR4331/K9 for reference. ISR4331-V/K9 is similar with it..
Note:
①
USB Type B mini port
⑤
Management port
②
Serial console port
⑥
LEDs
③
USB Type A port
⑦
AC Power
④
AUX Port
⑧
Power switch
The LEDs include eight indicators.
Table 2 shows the LED descriptions.
Represents
Color
Description
POE0
POE PSU
Green
PoE is on and providing power.
Amber
PoE is in a failed condition.
Off
PoE supply is not present.
FLASH
System Flash Status
Blinking Green
Compact flash/eUSB flash is present and currently being accessed.
TEMP
Temperature Status
Solid green
All temperature sensors in the system are within acceptable range.
One or more temperature sensors in the system are outside the acceptable range.
Temperature is not being monitored.
PWR
System Power
System power is on and functioning correctly.
Green blinking
System power is in the process of shutting down.
System power is up, but low level initialization failed.
Amber blinking
System power is up, but the system failed to come out of reset.
System power is off.
SSD
mSATA Slot Status
SSD mSATA is present and enabled.
Initialized with error.
Not present.
ISC
ISC Slot Status
PVDM4 is present and enabled.
FAN
Fan Status
All fans are operating.
One fan has stopped working.
Blinking Amber
Two or more fans have stopped working, or the fan tray has been removed.
Fans are not being monitored.
STAT
System Status
System operating normally.
Blinking amber
BIOS/Rommon is booting.
BIOS/Rommon has completed booting, and system is at Rommon prompt or booting platform software.
System is not out of reset or BIOS image is not loadable.
Figure 3 shows the back panel of Cisco ISR4331/K9 for reference. ISR4331-V/K9 is similar with it..
RJ45 Ports
NIM Slots
SFP Ports
SM-X Slot
·① & ② : These four ports include one combo port, one RJ45 port and one SFP port. It means the RJ45 and SFP in the combo port can't be used at the same time.
·NIM slots support one double-wide or two signal-wide modules.
·An SM-X slot can be converted into a Network Interface Module (NIM) slot using an optional carrier card.
Cisco ISR4331-V/K9 (2GE,2NIM,1SM,4G FLASH,4G DRAM, Voice Bundle)
Enhanced service-module slots
Doublewide service-module slots
0
NIM slots
OIR (all I/O modules)
Yes
Default memory double-data-rate 3 (DDR3) error-correction-code (ECC) DRAM
(Combined control/services/data planes)
4 GB
Maximum memory DDR3 ECC DRAM (Combined control/services/data planes)
16 GB
Default memory DDR3 ECC DRAM (data plane)
NA
Maximum memory DDR3 ECC DRAM (data plane)
Default memory DDR3 ECC DRAM (control/services plane)
Maximum memory DDR3 ECC DRAM (control/services plane)
Default flash memory
Maximum flash memory
External USB 2.0 slots (type A)
USB console port -type B mini (up to 115.2 kbps)
Serial console port - RJ45 (up to 115.2 kbps)
Serial auxiliary port - RJ45
(up to 115.2 kbps)
Redundant power supply
N/A
AC input voltage
100 to 240 VAC autoranging
AC input frequency
47 to 63 Hz
AC input current range, AC power supply (maximum)
3 to 1.3A
AC input surge current
60 A peak and less than 5 Arms per half cycle
Typical power (no modules) (watts)
42
Maximum power with AC power supply (watts)
250
Maximum power with PoE power supply (platform only) (watts)
530
Maximum endpoint PoE power available from PoE power supply (watts)